Showing results: 1 - 15 of 338 items found.
-
PT2 -
Shanghai Powoo Industry Develop Group Limited
- completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - the lead wire has a pin format, which makes it easy to be fixed on a PCB; - the mechanical dimensions for this series of PTs are relatively small, hence can be used an electronic component; - good linearity, high precision, wide operating range; - ABS anti-combustion plastic casing; - encapsulated with epoxy resin to ensure strong insulation ability.
-
PT4 -
Shanghai Powoo Industry Develop Group Limited
- completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - the lead wire has a pin format, which makes it easy to be fixed on a PCB; - the mechanical dimensions for this series of PTs are relatively small, hence can be used an electronic component; - good linearity, high precision, wide operating range; - ABS anti-combustion plastic casing; - encapsulated with epoxy resin to ensure strong insulation ability.
-
-
-
-
Neutronics Manufacturing Co.
We, NMC, are engaged in manufacturing AC/DC High Voltage Transformers ranging from 5kv upto 150Kv having current capacity from 10mA to 200mA AC/DC in Air cooled or Oil Cooled type as per the customer requirement.
-
WP-36000 -
The Eastern Specialty Company
The WP-36000 Transformer is primarily a laboratory standard. The high degree of accuracy and multiplicity of ranges makes this transformer the standard for precision calibration work. With the aid of this transformer, very accurate determination can be made of the ratio and phase angle characteristics of voltage transformers having ratings from 14,400 to 36,000 volts.
-
KATC-V2 -
The Eastern Specialty Company
Knopp’s KATC-V2 is a highly accurate state-of-the-art voltage transformer comparator that is compatible with all older generation Knopp comparators, and is designed to be a direct, plug-in replacement with additional test set cables to fit in the existing Knopp Voltage Transformer Test Systems.
-
ZERA GmbH
In this category you will find components for high-voltage testing as well as for testing electronic or conventional voltage measuring transformers.
-
KVTS -
Knopp Incorporated
The Knopp Voltage Transformer Testing System is designed to measure the accuracy of instrument transformers having 120 volt secondaries and up to 14,400 volt primaries (special order for up to 36,000 volt primaries is available). The system includes a control console which contains the control circuitry, ANSI standard burdens, and the Knopp Automatic Transformer Comparator. The Knopp precision and loading transformer set is also included (as pictured) and is connected to the console via a special cable.
-
KVTS -
The Eastern Specialty Company
The Knopp Voltage Transformer Testing System is designed to measure the accuracy of instrument transformers having 120 volt secondaries and up to 14,400 volt primaries (special order for up to 36,000 volt primaries is available). The system includes a control console which contains the control circuitry, ANSI standard burdens, and the Knopp Automatic Transformer Comparator. The Knopp precision and loading transformer set is also included (as pictured) and is connected to the console via a special cable.
-
YDQ -
Wuhan Sangao Electrical Test Installations Limit Co.
PD-free HV Testing Transformer is a high-end testing transformer which firstly marketed in China by our company. The High-light characteristic of the equipment reflects the smallness in size, lighter in weight clean, oil-free, unnecessary static of field investigation, longer working life without maintenance and slightness in non-partial discharge. It is used for the insulators' voltage-resistance testing.
-
2J6 -
The Eastern Specialty Company
The Type 2J6 Knopp Uniload Voltage Transformer Test Set consists of three major parts: When the Knopp Precision Transformer in the 2J6 set is compensated for, and used with, a secondary burden of 15 volt-amperes, for example, the ratio of this precision transformer is well within 0.02% and the phase angle is well within 2 minutes. The transformer, in common with other Knopp Precision Multirange Transformers, is wound so that it has practically the same ratio and phase angle accuracy on all ranges.
-
GTU-400KVA/400KV -
Wuhan Sangao Electrical Test Installations Limit Co.
GTU high-voltage testing transformer uses SF6 as the insulating gas to separate the vacuum room from the outside, this equipment reflects the smallness in size, lighter in weight, higher voltage grade for unit, convenience in transportation and operation, It can let the large capacity and high voltage power frequency transformer arrived at the scene for the high-voltage test.
-
GTU-1200KVA/600KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.